Counterflow Cooler
The Crocus Counterflow Cooler is designed to cool and dry extruded and heat-treated feed and pellets.
The Cooler is available in two designs for flexibility of installation. The square cooler can be supplied with an inlet capacity of up to 60 tons/hour and the round cooler up to 40 tons/ hour. A relatively low aerodynamic resistance
|
|
|
(due to the design of the discharge section) ensures a relatively low energy consumption. The cooler can be equipped with a discharge hopper for fast change over. The system is both economic and effective compared with other systems.
See “Technical data” for details.
|
 |
|
|
|
|
| CCS |
| Type |
100 |
101 |
150 |
151 |
200 |
201 |
250 |
251 |
300 |
301 |
350 |
351 |
Capacity (t/h):
Pillet size:
4 mm, 650 kg/m3
Water content:
15 - 16%
Fat content: 4 - 6%
Air volume:
900 - 1200 m3/t/h
Resistance:
1000 - 1500 Pascal |
10 |
15 |
15 |
20 |
25 |
30 |
35 |
40 |
45 |
50 |
55 |
60 |
| Area (m2) |
3,6 |
4,4 |
5,2 |
6,1 |
7,1 |
8,1 |
9,3 |
10,4 |
11,7 |
13,0 |
14,5 |
15,9 |
|
|
|
| CCR |
| Type |
100 |
150 |
200 |
250 |
300 |
350 |
Capacity (t/h):
Pillet size:
4 mm, 650 kg/m3
Water content:
15 - 16%
Fat content: 4 - 6%
Air volume:
900 - 1200 m3/t/h
Resistance:
1000 - 1500 Pascal |
10 |
15 |
20 |
25 |
30 |
35 |
| Area (m2) |
2,9 |
4,1 |
5,6 |
7,3 |
9,1 |
11,3 |
|
|
|
|
|
|
|
|
|
|
|